SANYOSEIKO SK-8000
Brief introduction to the characteristics of SANYOSEIKO Shanyang seiko SK-8000 high temperature observation device;
The sample size that can be observed is 50×50mm, and large parts can also be observed.
Can be heated up to 800 C.
Using near infrared halogen heating core, the top and side of the sample are heated by radiation, and the bottom of the sample is heated by stage heat conduction, so that the sample can be heated uniformly in all directions.
The maximum heating rate is 250℃/min(≒4.2℃/sec), and the unit with temperature curve of, 1℃ and 1sec can be set to 127 stages.
Top observation and side observation can be carried out at the same time, so the situation of missing observation can be prevented and the observation accuracy is quite high; The observation angle of the inclined plane can be adjusted from 0 to 15 degrees based on the level, and the state of BGA and CSP during melting and solidification can be continuously observed, and the deformation of printed wiring board during heating and cooling can also be observed. Because of the resolution of 10μm, the size of solder paste powder particles can be observed.
The observation magnification can be 8-260 times on a 17-inch display, and samples can be observed at the most appropriate magnification from 0603-sized patch parts to BGA packaging; If you have special needs, you can order a product that can be magnified 520 times on a 17-inch monitor for observation.
Use the gas circulation replacement tool to make the gas in the heated cavity flow, and discharge the smoke generated by the sample and the organic matter turned into gas out of the heating cavity to prevent the image quality deterioration caused by the smoke and the organic matter turned into gas, so as to obtain a stable and high-quality picture.
The images on the monitor and the images recorded on the hard disk can be simply inserted with comments such as ① the temperature in the heating chamber, ② the elapsed time since heating, ③ the record of test length or reference scale, ④ the characteristics of the sample and the sample number.
According to these information, the real-time state of the sample can be observed on the image when the temperature changes.
The animation image data is digitized and converted into MPEG-2 code format and then stored in the hard disk to prevent the deterioration of image quality.
For animation image recording, HD (hard disk) is used to record the top observation image and inclined observation image, and one 140GB hard disk is used for each image observation surface to record data, totaling two pieces, and the total recording time is about 40 hours each.
Recorded images can be played back at the same time, and at the same time, the operation of dragging the slider to the desired time point can be carried out quickly, and the playback operation can be carried out conveniently, so the test situation can be confirmed simply and conveniently.
Editing animated images and switching from still images, with the help of the built-in editing software, the edited images can be processed on the computer, for example, a 5-minute experiment, an important simplified image between 30 seconds and 1 minute can be intercepted for editing, and it is convenient to use in occasions such as introduction and explanation.
Many still images can be captured by the built-in still image capture software, which can be used as continuous still images for explaining phenomena when making reports or introducing data; These animated images and edited animated images also include still images, which can be burned into CD (mini-disc) and DVD by using the built-in mini-player.
Using the built-in measuring software, it is convenient to measure the length, angle and area of the upper part of the intercepted still picture, and a chart can be drawn based on these measured values plus time and temperature changes; That is, the change process can be digitized and graphically displayed, and these charts can be used for phenomenon evaluation and analysis; In terms of area calculation, the areas of circles, ellipses, quadrangles and polygons can be calculated instantly.
Let the nitrogen in the heating chamber flow and change the air into nitrogen, thus creating a nitrogen environment; The nitrogen environment is replaced by flow, which is used in conjunction with the lifting concentration meter and the gas flow replacement tool to control the oxygen concentration in the heating cavity within an expected value, even during the heating process.
Can be heated in a vacuum environment of 13Pa (grade).
Temperature curve for solder reflow for 3 ~ 4 minutes, 5 ~ 6 samples/hour detection (including cooling time of heating chamber)
Daily maintenance:
Using the attached special joystick, the daily maintenance of the observation window can be completed within 30 seconds; The difficulty of this maintenance is equivalent to inserting the sample into the main engine, which can reduce the burden on the engineer. In addition, the cleaning of the heating chamber can be completed in 3 ~ 5 minutes without using other joysticks. There is basically no need to disassemble the heating cavity for overhaul.
Environment required for equipment operation:
Commercial power supply and cooling water are needed to use this device, and the power input requirement is AC100V.