MALCOM SRS-1C
summary
Brief introduction to the characteristics of MALCOM SRS-1C reflux furnace simulation measuring device;
- By heating with hot air and far infrared rays below, the conditions close to the actual reflow furnace can be reproduced.
- By setting the system reflux heating, and can simply analyze the temperature curve data.
- With the image observation system, the image captured in the camera and its temperature curve can be output and saved < option >
- The furnace image analyzer can analyze the deformation of heated components, such as the height of CSP/BGAの solder ball and the evaluation of fillet weld shape (solder height and angle) of chip component 0402 size < option >.
parameter
Specification parameters of MALCOM SRS-1C reflux furnace simulation measuring device;
Substrate size | W70×L70 (mm) or less Thickness: the upper and lower sides of the holding surface are less than 10 mm. |
Device size | Heating furnace: W320×D285×H310 (mm) Control Department: W290×D235×H270 (mm) |
mode of heating | Above: hot air Below: Far infrared radiation |
Cooling mode | Flow regulating valve for cooling by introducing (nitrogen or air) external gas. |
Power Supply | 3-phase 200V, 50/60Hz, 3kVA |
External gas | 0.3~0.5MPa,100L/min (MAX) |
Oxygen concentration in the furnace (when nitrogen is used) | Minimum 100ppm (closed structure in furnace) |
Substrate tray | Flat tray |
Above heating | Hot air type: about 2.8kW (about 350W×8 series) Deviation can be set for standard nozzle. ※ |
Heating below | Infrared heater: about 360W W. |
Temperature accuracy | Within 5℃ (within the range of W50×L50mm in the center of the largest substrate) |
Measuring temperature | Normal temperature ~ 330℃ |
Determination points | 3 measuring point |
Nitrogen supply function | Flow regulating valve 25ml/min |
Special system for control | SRS-1CS corresponds to OS: Windows XP. |
Device weight | Body: about 15kg, control device: about 7.5kg |