HITACHI TM4000/TM4000Plus
summary
Introduction of TM4000/TM4000Plus Electron Microscope (Desktop)
- The picture quality is clearer, the operation is more convenient, and the viewing is more intuitive. TM4000 series is equipped with the latest technology to meet the "better" observation needs. Intuitive operation, supporting a series of operations such as making reports using target data.
TM4000/TM4000Plus Electron Microscope (Desktop) Features:
- In order to meet the customer's demand of "starting the equipment directly without sample pretreatment and obtaining the target sample data quickly and simply",TM4000 series has been comprehensively improved.
- Samples with a maximum diameter of 80 mm and a thickness of 50 mm can be observed. Built-in optical camera (optional) makes it easy to find the target sample.
- It only takes about 3 minutes from sample loading to image acquisition, which optimizes the original workflow from shape observation, element analysis to report production.
parameter
Specification parameters of TM4000/TM4000Plus electron microscope (desktop)
name of an article |
TM4000Plus |
TM4000 |
enlargement ratio |
×10~×100,000 (negative magnification) ×25~×250,000 (display magnification) |
|
acceleration voltage |
5 kV、10 kV、15 kV |
|
Image signal |
Backscattered electron secondary electron Synthesis (backscattered electrons+secondary electrons) |
Backscattered electron |
Vacuum mode |
Electrical conductor (backscattered electrons only) standard Reduce charge |
standard Reduce charge |
Image mode (backscattered electrons) | Standard (BSE), shadow image 1, shadow image 2, concave-convex topography image | |
Sample moving range |
X: 40 mm Y: 35 mm |
|
Maximum sample size | 80 mm (diameter) 50 mm (thickness) | |
electron gun |
Pre-aligned medium-sized tungsten filament |
|
explorer |
Backscattered electrons: High sensitivity 4-division backscattered electron detector Secondary electron: High sensitivity and low vacuum secondary electron detector |
Backscattered electrons: high sensitivity 4-division backscattered electron detector |
Automatic image adjustment function | Auto start, auto focus, auto brightness adjustment | |
Image storage pixel | 2,560×1,920 pixels, 1,280×960 pixels and 640×480 pixels. | |
picture format |
BMP、TIFF、JPEG |
|
the data shows that ... |
Ruler, micrometer value, magnification, date, time, imageNo. WD, comments, accelerating voltage, Vacuum mode, image mode, image signal |
|
Vacuum system (vacuum pump) |
Turbomolecular pump: 67 L/s 1 set. Diaphragm pump: 20 L/min |
|
Operation auxiliary function |
Electron beam rotation, preset magnification (level 3) Electron beam deflection (±50 µm @ WD6.0 mm) |
|
Safety function | With current protection function and built-in leakage circuit breaker | |
Size & weight |
Mainframe: 330 (length) ×614 (width) ×547 (height) mm, 52 kg(motor drive stage). Mainframe: 330 (length) ×617 (width) ×547 (height) mm, 52 kg(manual stage) Diaphragm pump: 144 (length) ×270 (width) ×216 (height) mm |