HIOKI FA1240-61/FA1240-63
summary
HIOKI Kaya Hioki flying needle tester FA1240-61/63 features one: data import is more convenient, faster and more accurate.
- It can be generated by importing from other electronic data: (FIT-LINE UA1780)
- Gerber data
- Monunt data
- Correct information can be obtained through five steps, and a physical substrate is not needed.
HIOKI Kaya Hioki flying needle tester FA1240-61/63 features two: simpler test and faster speed.
- According to the production procedure, the procedure is simple and easy to use.
- FA1240-61/63 can simply and quickly confirm the physical substrate.
- According to the design information of the substrate, the selection of test points and test needles is automatically calculated, which improves the working efficiency.
- And the simple high-speed test can be realized by sorting and combining the measuring points through the network information.
- Time is 10-15 times higher than that of the previous generation.
HIOKI Kaya Hioki flying needle tester FA1240-61/63 features three: faster confirmation of defects (FAIL VIEWER UA1782).
- FA1240-61/63 is equipped with FAIL VIEWER system software, which can search for defective parts without stopping the machine.
- FAIL VIEWER is equipped with a network search function for fashion testing other than defective components.
- FA1240-61/63 can not only test parallel components, but also search for the green oil window part where short circuit may occur.
HIOKI Kaya Hioki flying needle tester FA1240-61/63 features four: equipped with ultra-wear-resistant probes.
- More than 3 million times of stable contact can prevent poor contact.
- The probe can be simply replaced without special tools.
parameter
Specifications of HIOKI four-terminal flying needle tester FA1240-61/63:
name of an article |
FA1240-61 |
FA1240-63 |
Number of arms | 4 arms (L, ML, MR, R) | |
Test steps | 40,000 steps (maximum) | |
measuring range | Resistance: 400μ Ω ~ 40mΩ Capacitance: 1pF~400mF Inductance: 1μH~100H Diode VZ test: 0~25V Zener diode VZ test: 0~25V, 25~80V (optional) Digital triode: 0~25V Optocoupler: 0~25V Short circuit: 0.4Ω~400kΩ Road opening: 4Ω~40MΩ DC voltage test: 0~25V Functional voltage test: ±40V (option) Relay ON resistance test: 40m~40Ω (optional) FET ON resistance test: 400m~400Ω (option) Simple function test: ±25V (optional) |
|
Test speed |
0.025s/step~ |
0.025s/step~ |
positioning accuracy | Within 100μ m of each arm (in all directions of X-Y) | |
Moving repetition accuracy | Within 50μ m (test point position) | |
Minimum test needle gauge |
0.15 mm (4-terminal probe, 0.5 mm) |
0.15 mm (4 terminal probe, 0.5 mm) |
Test maximum size |
510W × 460D mm |
400W × 330D mm |
Power Supply |
AC200 V (single phase) 50/60 Hz 6 kva (AC230 V for fa1241) |
AC200 V (single phase)50/60 Hz 5 kVA |
Size and weight |
1406W × 1300H × 1380D mm 1150 kg |