MALCOM FCP-50
summary
Brief introduction to the characteristics of MALCOM FCP-50 display wave soldering furnace temperature curve system;
- The temperature in the wave soldering furnace tank can be stably and accurately managed.
- Analyze the welding temperature and wetting time from various angles through the attached special software; By inputting the conditions of preheating, welding temperature and time in the computer, the computer can automatically make a decision.
- For the measurement of welding curve that requires immediacy, the attached 0.1φ hot spot pair is the best choice.
- Not only the high temperature resistance is realized, but also the small size (・52mm width measured by 6ch) is light, and the connecting parts for connecting computers to transmit data are unnecessary.
- The cooling part can cool the memory well, and it is also equipped with a charging interface.
parameter
MALCOM FCP-50 shows the temperature curve of wave soldering furnace, and the system specifications;
Memory device | |
type | FCP-50 |
memory | RCM-62 |
Measuring temperature range | 0~500℃ |
Maximum measuring time | About 90 minutes |
Sampling period | 0.05 0.1 0.2 0.5 1.0 2.0 4.0 8.0 seconds (can be set at will) |
Temperature accuracy | ±1℃ |
Determination points | 1 ~ 6 o'clock |
Heat-resistant connector | Mini connector |
input | Thermocouple JIS-K, below 110Ω |
Power Supply | Lithium rechargeable battery (mini USB-B charging) |
data mode | USB |
outline dimension | W52×D255×H19 (mm) |
weight | About 500g |
Corresponding OS | Windows 2000/XP |
Pallet variable amplitude | 65~130mm(standard) |
Cooling parts | |
type | RCF-2 |
Power Supply | AC 100V~240(about 15W),50/60Hz |
Memory charging | With memory charging function (charging via USB) |
outline dimension | W340×D214×H108 (mm) |
weight | About 3.5kg |
※The measurement accuracy does not include the error of thermocouple and the error of reference contact temperature.