Main features of MALCOM RCX-GL furnace temperature tester series:
- RCX-GL can freely match the necessary test modules on the core memory (6CH temperature measurement).
- MALCOM has newly developed 12ch oxygen concentration RCX-O, in-furnace camera RCX-C, and wind speed measurement RCX-W modules for reflow furnace process management.
- The special analysis software TMR-1 can display oxygen, wind speed and camera animation on the same screen.
- The software TMR-1 has newly added the auxiliary setting function of furnace temperature curve, so that the ideal furnace temperature curve can be made simply.
- The battery can be a single 4-battery or a Ni-MH battery (option).
- Bluetooth transmission can transmit data wirelessly, or add WIFI module RCX-R.
- At the same time, it can save 20 groups of furnace temperature test data, which improves the efficiency of data acquisition.
- Thermocouple wire reminder function can avoid meaningless test when disconnection occurs.
- RCX-GL recently added a vibration measuring module RCX-SV.
Characteristics of core memory of RCX-S(SIX)6ch (channel) furnace temperature tester;
- The core temperature tester of RCX-GL series products has greatly improved the measurement function.
- A new system reference memory that greatly improves the performance of temperature measurement
- Equipped with thermocouple wire breaking function.
- Can save 20 test data, so it can correspond to multi-line continuous test (need cooling).
- Bluetooth transmission can read data without connecting a data line.
- Single 4 battery is used as power supply, and power display function is also equipped.
Specification parameters of RCX-S core memory 6ch:
measuring range |
0~500℃ |
Maximum determination time | 10 hours |
Sampling period (seconds) |
0.05,0.1,0.2,0.5,1.0,2.0,4.0,8.0(Can be set at will) |
Determination accuracy |
±1℃ |
Determination points | 1~6 o'clock |
Heat-resistant socket | Small thermocouple |
Power Supply |
Ordinary battery (single 4-battery AAA×3) Alkaline manganese battery, alkaline storage battery, nickel-hydrogen battery Rechargeable lithium battery (optional) |
data transmission |
USB/Bluetooth |
outline dimension |
Core memory: W55xD170xH18 (mm) Standard heat-resistant shell for RCX: W65xD245xH25 (mm) |
weight | About 550g (excluding bracket) |
12ch measuring module rcx-t (twelve)-Malcolm RCX-GL furnace temperature tester features:
- During the trial production of RCX-GL, the quality can be managed simply by changing from 6ch to 12ch.
- The 12ch temperature curve can be tested by adding it to the 6ch core memory.
- You can make new models or trial production at ordinary times, and replace the general 6ch temperature tester for evaluation.
12ch measurement module RCX-T specification parameters:
measuring range |
0~500℃ |
Maximum determination time | 3 hours |
Sampling period (seconds) |
0.05,0.1,0.2,0.5,1.0,2.0,4.0,8.0 (It can be set at will, just like the core memory RCM-S) |
Determination accuracy |
±1℃ |
Determination points | 1~12 o'clock |
Heat-resistant socket | Small thermocouple |
Thermocouple wire | Thermocouple JIS-K, less than 1KΩ (Ф0.1mm 10m) |
outline dimension |
Core memory: W55xD250xH25 (mm) Standard heat-resistant shell for RCX: W114xD250xH25 (mm) |
weight | About 1000g (excluding bracket) |
Commonly used modules
Malcom RCX-GL Furnace Temperature Tester Reflux Furnace Camera Module RCX-C;
- RCX-C High Temperature Resistant Camera Module for Shooting Actual State in Reflow Welding Furnace
- The camera is directly fixed on the base plate (thickness 19mm).
- Using reflective lenses, you can shoot from the side, top and inclined plane.
Specification parameters of camera module RCX-C:
project | specifications | |
form |
RCX-C< Reflux furnace camera > |
|
Maximum measuring time | Video recording is about 10 minutes (excluding batteries, heat-resistant time) | |
camera |
Pixel | 300,000 pixels |
field of vision |
Photographic distance/range About 4(W)× about 3 (h) mm (w.d.10 2 mm) ~ About 55(W)× about 41 (h) mm (w.d. 300 2 mm) |
|
illuminate |
LED |
|
Power Supply | The memory core is supplied with nickel hydrogen rechargeable battery (No.7 battery (AAA)×3) or lithium ion battery through < RCM-S >. | |
outline dimension |
Heat-resistant shell:(W)65mm×(D)370mm×(H)25mm Camera department:(W)44mm×(D)84mm×(H)19mm |
|
data mode |
W1110xD910xH1000 (mm)No protruding part |
|
weight | Memory core for camera+modular reflow oven tester: about 800g without tray; camera part: about 150g without tray. |
MALCOM reflow soldering oxygen analyzer RCX-O(OXYGEN);
- Because it is heat-resistant, it can measure and remember the oxygen concentration curve when it flows in the actual overheated reflux furnace.
- Being able to grasp the oxygen concentration state of each reflux zone is helpful to give the best installation conditions and equipment state.
- The measuring range can be selected from two types (50 ~ 5,000 ppm or 1,000 ~ 1000~10000ppm).
RCX-O specification parameters of reflow soldering oxygen analyzer:
Maximum determination time |
Ni-MH rechargeable battery: about 40 minutes Lithium rechargeable battery: about 80 minutes |
Sampling period (seconds) |
0.05、0.1、0.5、1.0、2.0、4.0、8.0、It can be set at will (like the core memory RCM-S). |
Determination principle | ZIRCONIASENSOR type |
measuring range |
50ppm~5000ppm、1000~10000ppm |
Determination accuracy |
50ppm~5000ppm ±5%FS 1000ppm~5000ppm ±10%FS 1000ppm~10000ppm ±5%FS |
Power Supply | Core memory (RCM-S) power supply Ni-MH rechargeable battery (single 4 battery (AAA)x3 or lithium rechargeable battery * Note 3 |
outline dimension | Heat-resistant shell for RCX: 65mm wide, 383mm long and 25mm thick without protruding parts. |
weight | About 950g (excluding bracket) |
* Note 3 Ordinary alkaline power supply cannot be used. Please choose rechargeable Ni-MH battery for purchase.
The wind speed measuring module RCX-W(WIND) of Malcom RCX-GL furnace temperature tester;
- The wind speed measuring module RCX-W(WIND) needs a special heat-resistant shell when it is used.
- The wind speed curve on the substrate can be measured.
- The wind speed sensor is installed on the substrate, which can measure the wind speed curve of the place of interest.
- RCX-W can be in the same production state, and the wind speed can be measured when the reflux furnace is heated.
- According to the placement direction of the wind speed sensor, the up-and-down or left-and-right wind speed can be measured.
Specification parameters of wind speed measuring module RCX-W:
Wind speed measuring range |
0.1~5m/s |
|
Determination accuracy |
Indicating value±(5%+0.1m/s) |
|
Sampling period (seconds) | 0.5 seconds | |
Determination points | 1 o'clock | |
outline dimension |
Core memory: 55mm wide, 285mm long and 18mm thick. Heat-resistant shell: 65mm wide, 383mm long and 25mm thick. |
|
weight | About 760g (excluding bracket) |
TMR-1 system software of Malcom RCX-GL furnace temperature tester;
- Different from the current temperature curve management, the reflow furnace process is comprehensively managed and evaluated from all angles.
- There is also a temperature curve prediction function that can make ideal conditions in a short time.
- The auxiliary furnace temperature curve setting function reduces the operation time.
- You can open the temperature curve of TPD file (the format of old analysis software TAM series).
- The temperature curve tester RCP-600/RCR-60/RCP-200 for reflow soldering is also compatible with this system.
- The above-mentioned temperature analysis program TAM series for reflow furnaces other than the corresponding models.
New module
MALCOM RCX-GL furnace temperature tester RCX-SV vibration sensor module;
- The vibration during the heating of the reflow oven is measured by two sensors RCX-SV.
- RCX-SV can measure the vibration of the track on the actual production line.
- Analyze the defects according to the vibration (when the reflow oven is heated)
- Confirm the track status and the connection between devices.
- The change of wind speed setting for vibration
MALCOM RCX-GL furnace temperature tester RCX-R wireless LAN module;
- Module for displaying temperature curve in real time
- RCX-R is safer and more secure when using WIFI.
- You can change the setting of reflux furnace while confirming the furnace temperature curve.
- RCX-R is equipped with memory function and data will not be lost.