summary
Features of flatness detection & reflux observation system core9032a;
- Characteristics of flatness measurement-reflux observation system Core9032a;
- Core9032a has the function of 3D measurement, which can intuitively grasp the warpage and distortion of the circuit board by using 3D colors.
- The hot air convection heating mode is adopted to truly restore the heating scene in the reflux furnace.
- The temperature curve used for heating can be easily made by inputting the temperature and time.
- Core9032a can automatically measure the coplanarity of the tested sample according to the temperature curve.
- The camera unit can observe the changes of components in the heating process in real time.
- The camera unit is equipped with an HDD recorder, which can measure the flatness and record the changes of components.
- The 9032a system can combine the captured video (image) and measured data to quickly generate the heating experiment report of the product.
parameter
Specification parameters of flatness detection & reflux observation system core9032a;
Power Supply |
AC 200V±5%,50/60Hz monophase |
|
Consume electricity | About 2200VA (host unit 100V 1900VA, control unit 100V 300VA) | |
driving wheel | 2-axis (x-y)5-phase micro stepping motor | |
Displacement sensor | Light source, wavelength | Semiconductor laser red, 670mm |
resolution ratio |
0.3μm |
|
Point diameter |
7μm |
|
Supply gas pressure |
0.6Mpa~0.9Mpa |
|
Gas consumption |
230L/min |
|
weight |
Host unit: 65Kg Control unit: 25kg Transformer unit: about 50kg. |
|
outline dimension |
Main unit: W760xD380xH540 (mm) without protruding part. Control unit: W295xD400xH400 (mm) does not contain protruding parts. The required area for setting the workbench: W:1800, D:750. Transformer unit: W435xD340xH285 (mm) without protrusions. |
|
Use ambient temperature |
25℃±3℃ |
Determination specification
Reflow welding observation/flatness tester Core9032a determination specification:
measure a distance | X axis 100mm, y axis 75 mm. | |
measuring range |
±1000μm |
|
precision |
±1% of reading ±2μm (When measured by reference film of our company) |
|
reproducibility |
5μm (When measured by reference film of our company) |
|
Data acquisition interval (coplanar) |
0.001mm、0.002mm、0.005mm、0.01mm、0.02mm、0.05、1mm,( Choose 0.01mm or more for 8mm/s, 0.02mm or more for 16mm/s and 0.05mm for 30 mm/s.※ |
|
Data acquisition interval (3D) | 0.01mm or more and 0.01mm interval (on the X-axis, 0.01mm or more for 8mm/s, 0.02mm or more for 16mm/s and 0.05mm or more for 30mm/s). | |
Measuring speed (coplanar 3d) |
0.1mm/s、0.2mm/s、0.5mm/s、1.0mm/s、2.0mm/s、4.0mm/s、8.0mm/s、16.0mm/s、30.0mm/s |
※Limited by the measuring speed
Core9032a heating specifications:
input | AC 200V, 220V, 240V (set before supply) 10%, 50/60Hz. |
output |
AC100V |
mode of heating | Using hot air (convection heating mode) |
output/actual monitor | Voltage representation accuracy is 2v. |
Heating range |
W120xD120xH25 (mm) |